Fluke 1732 and 1734 three-phase electrical energy loggers

Features

  • Key measurement functions: Automatically measure and record voltage, current, power, power factor, energy and associated values
  • Convenient connection of the instrument: The instrument is powered directly from the measured circuit
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III approved for service input and downstream circuits

With the new Fluke 1732 and 1734 three-phase electrical energy loggers introduce a new easy way to find the sources of energy waste. Discover where and when energy is consumed within your installation, from service inputs to individual circuits. Remotely view and share data with your team via the Fluke Connect® app, allowing you to maintain safer working distances and make important decisions in real-time. This reduces the need for protective equipment, site visits and checks.

Profiling energy consumption within your facility helps you identify energy saving opportunities and provides you with the data needed to take action. With the new Energy Analyze software package, you can compare multiple data points over a long period of time to get a complete picture of energy consumption. The first step towards reducing energy bills.

  • Key measurement functions: Automatically measure and record voltage, current, power, power factor, energy and associated values with Fluke three-phase electrical energy loggers
  • Compatible with Fluke Connect®: View data locally on the instrument, via the Fluke Connect mobile app and desktop software or via your building's Wi-Fi network
  • Convenient connection of the instrument: The instrument is powered directly from the measured circuit
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III approved for service input and downstream circuits
  • Measure all three phases:With 3 flexible current clamps included
  • Comprehensive logging function: More than 20 individual log sessions can be stored on the instruments. All measured values are even recorded automatically so you never lose measurement trends. They can even be accessed during recording sessions and before downloading for real-time analysis
  • Optimised user interface: Quick, graphical settings for which additional information is available allow you to capture the right data every time, and the intelligent monitoring function ensures that the right connections have been made, reducing user uncertainty
  • Bright colour touchscreen: Useful analysis and verification of data can be carried out in the field, with full graphical display
  • Optimised user interface: Always capture the right data with fast, guided graphic setup, and eliminate uncertainty about connections with the intelligent control function
  • Complete on-site installation via front panel: No need to go back to the workshop to download and install or take a computer to the electrical distributor
  • Fully integrated logging function: Connect other Fluke Connect instruments to the Fluke 1734 to record two other measurement parameters simultaneously. You can choose almost any parameter on a wireless digital multimeter or module with Fluke Connect*
  • Application software Energy Analyze Plus: Download and analyse every detail of energy consumption using our automated reports

 

Accuracy
Parameter Reach Resolution Intrinsic accuracy under reference conditions (% of readout + % of full scale)
Tension 1000 V 0,1 V ±(0.2% + 0.01%)
Power: direct input i17xx-flex 1500 12″ 150 A 0,1 A ±(1% + 0.02%)
1500 A 1 A ±(1% + 0.02%)
i17xx-flex 3000 24″ 300 A 1 A ±(1% + 0.03%)
3000 A 10 A ±(1% + 0.03%)
i17xx-flex 6000 36″ 600 A 1 A ±(1.5% + 0.03%)
6000 A 10 A ±(1.5% + 0.03%)
i40s-EL current clamp 4 A 1 mA ±(0.7% + 0.02%)
40 A 10 mA ±(0.7% + 0.02%)
Frequency 42.5 Hz to 69 Hz 0.01 Hz ±(0.1%)
Additional entrance ±10 V dc 0.1 mV ±(0.2% + 0.02%)
Voltage, min/max 1000 V 0,1 V ±(1% + 0.1%)
Current, min/max Defined by accessory Defined by accessory ±(5% + 0.2%)
Total harmonic distortion (THD) of the voltage 1000% 0,1% ±0,5
Total harmonic distortion of the current 1000% 0,1% ±0,5
Intrinsic uncertainty ± (% of readout + % of range)¹
Parameter Influence magnitude iFlex1500-12 iFlex3000-24 iFlex6000-36 i40S-EL
150 A / 1500 A 300 A / 3000 A 600 A / 6000 A 4 A / 40 A
Active power P PF ≥ 0.99 1,2% + 0,005% 1,2% + 0,0075% 1,7% + 0,0075% 1,2% + 0,005%
Active energy Ea PF ≥ 0.99 1,2% + 0,005% 1,2% + 0,0075% 1,7% + 0,0075% 1,2% + 0,005%
Apparent power S 0 ≤ PF ≤ 1 1,2% + 0,005% 1,2% + 0,0075% 1,7% + 0,0075% 1,2% + 0,005%
Apparent energy Eap 0 ≤ PF ≤ 1 1,2% + 0,005% 1,2% + 0,0075% 1,7% + 0,0075% 1,2% + 0,005%
Reactive power Q 0 ≤ PF ≤ 1 2.5% of measured apparent power
Reactive energy Er 0 ≤ PF ≤ 1 2.5% of measured apparent power
Labour factor PF - ±0,025
Power factor of the ground harmonic - ±0,025
DBF/cosϕ - ±0,025
’Additional uncertainty in% of range' P-N>250 V 0,015% 0,0225% 0,0225% 0,015%
¹Range = 1000 V x Irange
Reference conditions:

  • Surroundings: 23 °C ±5 °C, instrument operated for at least 30 minutes, no external electric/magnetic field, relative humidity <<65%
  • Entry conditions: Cosϕ/PF=1, sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10%.
  • Power and power specifications: input voltage 1 phase: 120 V/230 V or 3 phase star/delta: 230 V/400 V, input current: I > 10% of I range
  • Primary conductor of current clamps or Rogowski coil in central position 
  • Temperature coefficient: plus 0.1 x the specified accuracy for each degree C above 28 °C or below 18 °C

 

Electrical specifications
Nutrition
Voltage range 100 V to 500 V using protected plug-in input when current from the measured circuit is used
100 V to 240 V when using standard power cord (IEC 60320 C7)
Power consumption Maximum 50 VA (max. 15 VA when current is used via IEC 60320 input)
Efficiency ≥ 68.2% (in accordance with energy efficiency rules)
Maximum consumption without load < 0.3 W only when current is used via IEC 60320 input
Mains frequency 50/60 Hz ±15%
Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable
Battery life Four hours in standard operating mode, up to 5.5 hours in energy-saving mode
Charging time < 6 hours
Data acquisition
Resolution 16-bit synchronous sampling
Sample frequency 10.24 kHz at 50/60 Hz, synchronised with frequency of mains supply
Input signal frequency 50/60 Hz (42.5 to 69 Hz)
Circuit types 1-φ, 1-φ IT, split phase, 3-φ triangle, 3-φ star, 3-φ star IT, 3-φ star symmetric, 3-φ Aron/Blondel (2-element triangle), 3-φ triangle open lay, single currents (load studies)
Data storage Internal Flash memory (cannot be replaced by the user)
Memory Normal 10 log sessions of 8 weeks with 1-minute intervals and 500 events¹
¹The number of possible logging sessions and the logging period depend on user requirements.
Base interval
Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Average interval User-selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Average time for minimum/maximum values Voltage, current: RMS full cycle every half cycle updated Aux, power: 200 ms
Requirement interval (Energy meter mode)
Measured parameters Energy (Wh, varh, VAh), PF maximum requirement, energy cost
Interval Adjustable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Compliance with standards
Nutrition IEEE 1459
Interfaces
USB-A File transfer via USB flash drive, firmware updates 
Max. current: 120 mA
WiFi File transfer and remote control via direct connection or Wi-Fi
Bluetooth Reading additional measurement data from Fluke Connect® 3000 series modules (requires the 1734 or the optional upgrade for the 1732)
USB mini Downloading data to PC
Voltage inputs
Number of inputs 4 (3 phases and the neutral)
Maximum input voltage 1000 Vrms, CF 1.7
Input impedance 10 MΩ
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scale setting 1:1 and variable
Measurement category 1000 V CAT III/600 V CAT IV
Power inputs
Number of inputs 3, Mode is automatically selected for connected sensor
Input voltage Terminal input: 500 mVrms/50 mVrms; CF 2.8
Rogowski sinkhole 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Reach 1 A to 150 A/10 A to 1500 A with thin flexible current clamp i17XX-flex1500 12″
3 A to 300 A/30 A to 3000 A with thin flexible current clamp i17XX-flex3000 24″
6 A to 600 A/60 A to 6000 A with thin flexible current clamp i17XX-flex6000 36″
40 mA to 4 A/0.4 A to 40 A with 40 A terminal i40s-EL
Bandwidth (-3 dB) 42.5 Hz - 3.5 kHz
Scale setting 1:1 and variable
Auxiliary inputs
Number of inputs =”2″
Input range 0 to ± 10 V dc, 1 readout/s
Scale factor (available 2014) Format: mx + b (gain and deviation) user-configurable
Units displayed (available 2014) User-configurable (7 characters, e.g. °C, psi, or m/s)
Wireless connection
Number of inputs =”2″
Supported modules Fluke Connect® 3000 series
Acquisition 1 measurement/s
Environmental specifications
Operating temperature -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature -20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F)
Relative humidity during operation 10 °C to 30 °C (50 °F to 86 °F) max. 95% RH
30 °C to 40 °C (86 °F to 104 °F) max. 75% RH
40 °C to 50 °C (104 °F to 122 °F) max. 45% RH
Operating height 2000 m (maximum 4000 m reduce to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Height when stored 12.000 m
Housing IP50 in accordance with EN60529
Vibration measurement MIL-T-28800E, Type 3, Class III, Style B
Safety IEC 61010-1
IEC power input: overvoltage category II, pollution degree 2
Voltage connections: overvoltage category IV, pollution degree 2
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
Electromagnetic compatibility EN 61326-1: Industrial CISPR 11: group 1, class A
Korea (KCC): class A equipment (industrial transmission and communication equipment)
USA (FCC):47 CFR 15 subpart B. This product is considered an exempt device under clause 15.103.
Temperature coefficient 0.1 x accuracy specification/°C
General specifications
Colour LCD display 4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch screen
Warranty Instrument and power supply: Two years (except battery)
Accessories: one year
Calibration cycle: two years
Dimensions Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 inches)
Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 inches)
Instrument with power supply connected: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 inches)
Weight Instrument: 1.1 kg (2.5 lb)
Power supply: 400 g (0.9 lb)
Protection against unauthorised operations Slot for Kensington lock
Specifications of i17xx-flex 1500 12″ flexible current clamp
Measuring range 1 to 150 A AC / 10 to 1500 A AC
Non-destructive flow 100 kA (50/60 Hz)
Intrinsic error at reference condition* ±0.7% of measured value
Accuracy 173x + iFlex ± (1% of reading + 0.02% of range)
Temperature coefficient over the operating temperature range 0.05% from readout/°C 0.09% from readout/°F
Operating voltage 1000 V CAT III, 600 V CAT IV
Probe cable length 305 mm (12 in)
Probe cable diameter 7.5 mm (0.3 in)
Minimum bending radius 38 mm (1.5 in)
Output cable length 2 m (6.6 ft)
Weight 115 g
Cable material TPR
Material coupling POM + ABS/PC
Output cable TPR/PVC
Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor being tested shall not exceed 80 °C (176 °F)
Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating 15% to 85%, non-condensing
Protection class IEC 60529:IP50
Warranty One year
*Reference circumstance:

  • Environment: 23 °C ± 5 °C, no external electric/magnetic field, RV 65%
  • Primary conductor in central position

 

 

Download Datasheet

Need advice?

Contact our product specialist Thiara for help in choosing the right instrument.
Contact Thiara

Select at least 2 products
to compare