| Accuracy |
| Parameter |
Reach |
Resolution |
Intrinsic accuracy under reference conditions (% of readout + % of full scale) |
| Tension |
1000 V |
0,1 V |
±(0.2% + 0.01%) |
| Power: direct input |
i17xx-flex 1500 12″ |
150 A |
0,1 A |
±(1% + 0.02%) |
| 1500 A |
1 A |
±(1% + 0.02%) |
| i17xx-flex 3000 24″ |
300 A |
1 A |
±(1% + 0.03%) |
| 3000 A |
10 A |
±(1% + 0.03%) |
| i17xx-flex 6000 36″ |
600 A |
1 A |
±(1.5% + 0.03%) |
| 6000 A |
10 A |
±(1.5% + 0.03%) |
| i40s-EL current clamp |
4 A |
1 mA |
±(0.7% + 0.02%) |
| 40 A |
10 mA |
±(0.7% + 0.02%) |
| Frequency |
42.5 Hz to 69 Hz |
0.01 Hz |
±(0.1%) |
| Additional entrance |
±10 V dc |
0.1 mV |
±(0.2% + 0.02%) |
| Voltage, min/max |
1000 V |
0,1 V |
±(1% + 0.1%) |
| Current, min/max |
Defined by accessory |
Defined by accessory |
±(5% + 0.2%) |
| Total harmonic distortion (THD) of the voltage |
1000% |
0,1% |
±0,5 |
| Total harmonic distortion of the current |
1000% |
0,1% |
±0,5 |
| Intrinsic uncertainty ± (% of readout + % of range)¹ |
| Parameter |
Influence magnitude |
iFlex1500-12 |
iFlex3000-24 |
iFlex6000-36 |
i40S-EL |
| 150 A / 1500 A |
300 A / 3000 A |
600 A / 6000 A |
4 A / 40 A |
| Active power P |
PF ≥ 0.99 |
1,2% + 0,005% |
1,2% + 0,0075% |
1,7% + 0,0075% |
1,2% + 0,005% |
| Active energy Ea |
PF ≥ 0.99 |
1,2% + 0,005% |
1,2% + 0,0075% |
1,7% + 0,0075% |
1,2% + 0,005% |
| Apparent power S |
0 ≤ PF ≤ 1 |
1,2% + 0,005% |
1,2% + 0,0075% |
1,7% + 0,0075% |
1,2% + 0,005% |
| Apparent energy Eap |
0 ≤ PF ≤ 1 |
1,2% + 0,005% |
1,2% + 0,0075% |
1,7% + 0,0075% |
1,2% + 0,005% |
| Reactive power Q |
0 ≤ PF ≤ 1 |
2.5% of measured apparent power |
| Reactive energy Er |
0 ≤ PF ≤ 1 |
2.5% of measured apparent power |
| Labour factor PF |
- |
±0,025 |
| Power factor of the ground harmonic |
- |
±0,025 |
| DBF/cosϕ |
- |
±0,025 |
| ’Additional uncertainty in% of range' |
V P-N>250 V |
0,015% |
0,0225% |
0,0225% |
0,015% |
¹Range = 1000 V x Irange Reference conditions:
- Surroundings: 23 °C ±5 °C, instrument operated for at least 30 minutes, no external electric/magnetic field, relative humidity <<65%
- Entry conditions: Cosϕ/PF=1, sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10%.
- Power and power specifications: input voltage 1 phase: 120 V/230 V or 3 phase star/delta: 230 V/400 V, input current: I > 10% of I range
- Primary conductor of current clamps or Rogowski coil in central position
- Temperature coefficient: plus 0.1 x the specified accuracy for each degree C above 28 °C or below 18 °C
|
| Electrical specifications |
| Nutrition |
| Voltage range |
100 V to 500 V using protected plug-in input when current from the measured circuit is used |
| 100 V to 240 V when using standard power cord (IEC 60320 C7) |
| Power consumption |
Maximum 50 VA (max. 15 VA when current is used via IEC 60320 input) |
| Efficiency |
≥ 68.2% (in accordance with energy efficiency rules) |
| Maximum consumption without load |
< 0.3 W only when current is used via IEC 60320 input |
| Mains frequency |
50/60 Hz ±15% |
| Battery |
Li-ion 3.7 V, 9.25 Wh, customer-replaceable |
| Battery life |
Four hours in standard operating mode, up to 5.5 hours in energy-saving mode |
| Charging time |
< 6 hours |
| Data acquisition |
| Resolution |
16-bit synchronous sampling |
| Sample frequency |
10.24 kHz at 50/60 Hz, synchronised with frequency of mains supply |
| Input signal frequency |
50/60 Hz (42.5 to 69 Hz) |
| Circuit types |
1-φ, 1-φ IT, split phase, 3-φ triangle, 3-φ star, 3-φ star IT, 3-φ star symmetric, 3-φ Aron/Blondel (2-element triangle), 3-φ triangle open lay, single currents (load studies) |
| Data storage |
Internal Flash memory (cannot be replaced by the user) |
| Memory |
Normal 10 log sessions of 8 weeks with 1-minute intervals and 500 events¹ |
| ¹The number of possible logging sessions and the logging period depend on user requirements. |
| Base interval |
| Measured parameters |
Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy |
| Average interval |
User-selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min |
| Average time for minimum/maximum values |
Voltage, current: RMS full cycle every half cycle updated Aux, power: 200 ms |
| Requirement interval (Energy meter mode) |
| Measured parameters |
Energy (Wh, varh, VAh), PF maximum requirement, energy cost |
| Interval |
Adjustable: 5 min, 10 min, 15 min, 20 min, 30 min, off |
| Compliance with standards |
| Nutrition |
IEEE 1459 |
| Interfaces |
| USB-A |
File transfer via USB flash drive, firmware updates Max. current: 120 mA |
| WiFi |
File transfer and remote control via direct connection or Wi-Fi |
| Bluetooth |
Reading additional measurement data from Fluke Connect® 3000 series modules (requires the 1734 or the optional upgrade for the 1732) |
| USB mini |
Downloading data to PC |
| Voltage inputs |
| Number of inputs |
4 (3 phases and the neutral) |
| Maximum input voltage |
1000 Vrms, CF 1.7 |
| Input impedance |
10 MΩ |
| Bandwidth (-3 dB) |
42.5 Hz - 3.5 kHz |
| Scale setting |
1:1 and variable |
| Measurement category |
1000 V CAT III/600 V CAT IV |
| Power inputs |
| Number of inputs |
3, Mode is automatically selected for connected sensor |
| Input voltage |
Terminal input: 500 mVrms/50 mVrms; CF 2.8 |
| Rogowski sinkhole |
150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
| Reach |
1 A to 150 A/10 A to 1500 A with thin flexible current clamp i17XX-flex1500 12″ |
| 3 A to 300 A/30 A to 3000 A with thin flexible current clamp i17XX-flex3000 24″ |
| 6 A to 600 A/60 A to 6000 A with thin flexible current clamp i17XX-flex6000 36″ |
| 40 mA to 4 A/0.4 A to 40 A with 40 A terminal i40s-EL |
| Bandwidth (-3 dB) |
42.5 Hz - 3.5 kHz |
| Scale setting |
1:1 and variable |
| Auxiliary inputs |
| Number of inputs |
=”2″ |
| Input range |
0 to ± 10 V dc, 1 readout/s |
| Scale factor (available 2014) |
Format: mx + b (gain and deviation) user-configurable |
| Units displayed (available 2014) |
User-configurable (7 characters, e.g. °C, psi, or m/s) |
| Wireless connection |
| Number of inputs |
=”2″ |
| Supported modules |
Fluke Connect® 3000 series |
| Acquisition |
1 measurement/s |
| Environmental specifications |
| Operating temperature |
-10 °C to +50 °C (14 °F to 122 °F) |
| Storage temperature |
-20 °C to +60 °C (-4 °F to 140 °F), with battery: -20 °C to +50 °C (-4 °F to 122 °F) |
| Relative humidity during operation |
10 °C to 30 °C (50 °F to 86 °F) max. 95% RH |
| 30 °C to 40 °C (86 °F to 104 °F) max. 75% RH |
| 40 °C to 50 °C (104 °F to 122 °F) max. 45% RH |
| Operating height |
2000 m (maximum 4000 m reduce to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
| Height when stored |
12.000 m |
| Housing |
IP50 in accordance with EN60529 |
| Vibration measurement |
MIL-T-28800E, Type 3, Class III, Style B |
| Safety |
IEC 61010-1 |
| IEC power input: overvoltage category II, pollution degree 2 |
| Voltage connections: overvoltage category IV, pollution degree 2 |
| IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V |
| Electromagnetic compatibility |
EN 61326-1: Industrial CISPR 11: group 1, class A |
| Korea (KCC): class A equipment (industrial transmission and communication equipment) |
| USA (FCC):47 CFR 15 subpart B. This product is considered an exempt device under clause 15.103. |
| Temperature coefficient |
0.1 x accuracy specification/°C |
| General specifications |
| Colour LCD display |
4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch screen |
| Warranty |
Instrument and power supply: Two years (except battery) |
| Accessories: one year |
| Calibration cycle: two years |
| Dimensions |
Instrument: 19.8 x 16.7 x 5.5 cm (7.8 x 6.6 x 2.2 inches) |
| Power supply: 13.0 x 13.0 x 4.5 cm (5.1 x 5.1 x 1.8 inches) |
| Instrument with power supply connected: 19.8 x 16.7 x 9 cm (7.8 x 6.6 x 3.5 inches) |
| Weight |
Instrument: 1.1 kg (2.5 lb) |
| Power supply: 400 g (0.9 lb) |
| Protection against unauthorised operations |
Slot for Kensington lock |
| Specifications of i17xx-flex 1500 12″ flexible current clamp |
| Measuring range |
1 to 150 A AC / 10 to 1500 A AC |
| Non-destructive flow |
100 kA (50/60 Hz) |
| Intrinsic error at reference condition* |
±0.7% of measured value |
| Accuracy 173x + iFlex |
± (1% of reading + 0.02% of range) |
| Temperature coefficient over the operating temperature range |
0.05% from readout/°C 0.09% from readout/°F |
| Operating voltage |
1000 V CAT III, 600 V CAT IV |
| Probe cable length |
305 mm (12 in) |
| Probe cable diameter |
7.5 mm (0.3 in) |
| Minimum bending radius |
38 mm (1.5 in) |
| Output cable length |
2 m (6.6 ft) |
| Weight |
115 g |
| Cable material |
TPR |
| Material coupling |
POM + ABS/PC |
| Output cable |
TPR/PVC |
| Operating temperature |
-20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor being tested shall not exceed 80 °C (176 °F) |
| Temperature, non-operating |
-40 °C to +80 °C (-40 °F to 176 °F) |
| Relative humidity, operating |
15% to 85%, non-condensing |
| Protection class |
IEC 60529:IP50 |
| Warranty |
One year |
*Reference circumstance:
- Environment: 23 °C ± 5 °C, no external electric/magnetic field, RV 65%
- Primary conductor in central position
|
|
|
|
|