Graphtec GL7000 central unit with USB and Ethernet interface

Manufacturer: Graphtec
Central unit for the GL7000 modular measurement data acquisition system
For different measuring signals
up to 10 modules, max. 112 channels
4 pulse / logic channels
4 alarm outputs
Sampling interval between 1 μs and 1 hour, depending on module
With high-speed voltage module, max sampling frequency 1 μs
up to 2 million measurement points in internal RAM,
optional SD card or SSD hard disk
Category:

Modular acquisition system for measurement data

The modular data logger consists of a central unit, several input modules and is expandable with a display unit and an additional memory module (SDD). Up to 10 modules can be connected to a central unit.

The GL7000 has RAM memory for 2 million samples and built-in flash memory of 2 GB. Alternatively, the data logger can also store measured values on an external SD card (up to 32 GB) or in the SSD memory module. Automatic data backup possible.

Data recording can be started and stopped manually on the device, via an external trigger or time-controlled. The individually adjustable alarm output can be used to monitor the individual measurement channels and offers in addition to min or max. Configuration and data recording are also possible directly on the PC via a USB interface.

Depending on the structure, the logger has up to 112 input channels.

Input module: e.g. GL7-M for bipolar voltage and temperature (TC, Pt)

channels 10 analogue input channels
Voltage ranges ± 20, ± 50, ± 100, ± 200, ± 500 mV; ± 1, ± 2, ± 5, ± 10, ± 20, ± 50 V and 1-5 V.
Thermocouples Type K, J, E, T, R, S, B, N, W (WRe5-26)
Measurement intervals 10 ms to 1 hour (10 ms with 1 channel)
resolution 16 bit (effective resolution: 1/40000 of the entire measuring range)
Input resistor 1 MO +/- 5%

Central unit

4 pulse / logic channels max. 50,000 pulses per measuring interval, requires option B-513 alarm output cable
4 alarm outputs Open collector, can be activated from any channel, requires option B-513 alarm output cable
Getting things going for starting or stopping the measurement via date/time, measured value, status or counter input
filter Moving average of 2, 5, 10, 20, 40 readings
Storage 2 GB flash
optional storage on SD card (up to 32 GB) or SSD (about 64 GB)
Screen unit
(optional)
5.7-inch (145 mm) colour TFT
couple Ethernet, USB
Network function WEB server, FTP server, FTP client, NTP client, DHCP client
Power supply Power adapter: 100 to 240 V, 50/60 Hz
Dimensions approximately 193 x 141 x 160 mm
Weight approximately 2 kg
  • GLET-B513-KA-BA4-moduleItem number: GLET-B513-KA-BA4

    Passive module housing for trigger and logic inputs and alarm outputs as open collector

    for GL2xx, GL8xx and GL900 data loggers

Download datasheet
Download Manual

Need advice?

Contact our product specialist Thiara for help in choosing the right instrument.
Contact Thiara

Select at least 2 products