The Fluke a3002 FC wireless AC/DC current clamp module is designed for use with the i410 or i1010 AC/DC current clamps (not included with this module). The a3002 FC AC/DC current module wirelessly transmits readings to other Fluke Connect™-enabled main units, as shown below:
- Fluke 3000 FC DMM
- Fluke Ti200/300/400 thermal imaging camera
- PC via optional pc3000 FC adapter
- Fluke Connect Mobile App
Some of the key features of the Fluke a3002 FC:
- Measurement up to 400 A AC or 400 A DC with the i410 (sold separately)
- Measurement up to 600 A AC or 1000 A DC with the i1010 (sold separately)
- Use as a stand-alone meter or as part of the system
- Log function for recording and storing up to 65,000 measured values
|
AC/DC current
|
|
Function
|
Reach
|
Resolution
|
Accuracy1
|
|
A DC
|
1000 A
|
0,1 A
|
(0,5% + 3)
|
|
A AC
|
600,0 A
|
0,1 A
|
(1,0% + 3)
|
|
1 AC accuracy is specified from 45 Hz to 1000 Hz
|
|
Specifications
|
|
Maximum voltage between any connection and the safety earth (module)
|
30 V DC or AC RMS
|
|
Backlit LCD
|
3 ½ digits, 6000 counts, updated 4 times per sec.
|
|
Log speed/interval
|
Adjustable via PC from 1 second to 1 hour; default 1 minute
|
|
Battery type
|
2 AA alkaline batteries, NEDA 15A, IEC LR6
|
|
Battery life
|
Minimum 400 hours
|
|
Memory
|
Recording of up to 65,000 measured values
|
|
RF communication
|
2.4 GHz ISM band
|
|
RF communication range
|
Outside air, unobstructed: up to 20 m Obstructed, plasterboard wall: up to 6.5 m Blocked, concrete wall or steel electrical cabinet: up to 3.5 m
|
|
Operating temperature
|
-10 °C to +50 °C
|
|
Storage temperature
|
-40 °C to +60 °C
|
|
Temperature coefficient
|
0.1 X (specified accuracy)/°C ( 28 °C)
|
|
Relative humidity
|
0% to 90% (0 °C to 35 °C), 0% to 75% (35 °C to 40 °C), 0 % to 45 % (40 °C to 50 °C)
|
|
EMC
|
IEC 61236-1, portable
|
|
Safety specifications
|
Protected in accordance with IEC 61010-1, 600 V CAT IV / 1000 V CAT III, 3rd edition, pollution degree 2
|
|
Certifications
|
CSA, CE, FCC: T68-FBLE IC: 6627A-FBLE
|
|
Protection class (IP)
|
IP42
|
|
Dimensions (HxWxD)
|
160 mm x 66 mm x 38 mm
|
|
Weight
|
0.255 kg
|
Note: not suitable for Fluke CNX measuring instruments