Graphtec midiLogger HV GL2000 4-channel

Manufacturer: Graphtec

Fast, high-voltage, 4-channel data logger with display, up to 1000V CAT III

Input voltage ranges from ± 20mV ... ± 500V
DC-RMS voltage range 10 mV to 1000 V rms
Thermocouples type K, J, E, T, R, S, B, N, W
Sampling interval adjustable between 1 μs and 1 min
4 pulse / logic channels
4 alarm outputs
4 million measurement points per channel in internal flash memory,
external storage option on USB or SD card
Category:

Data logger with 4 multi-function inputs (voltage/temperature)

The HV GL2000 has an isolated input system, which ensures that signals are not affected by signal inputs on other channels. The multi-function inputs allow combined measurements of different measurement quantities such as voltage, temperature, humidity, logic and pulses.

  • Measurement of high voltage and actual effective value according to CAT III
  • Fast simultaneous voltage and temperature measurement with a sampling rate of 1 MS/s
  • Voltage measuring ranges (BNC connection)
    20 mV to 500 V DC, 1-5 V DC
    10 mV to 250 V rms
  • Thermocouples (screw terminal connection)
    K, J, E, T, R, S, B, N, W (WRe5-26)
  • Humidity 0 ... 100% RH (only with sensor B-530)

4 channels for logic/pulse/trigger

Four channels are available for logic and pulse input signals. The pulse mode can measure the following values for speed and flow: counter, pulses/sampling rate and revolutions per minute.

  • Humidity: 0 ... 100% RH (only with sensor B-530)
  • Pulse: 4 channels * (counter, pulses/sampling interval and revolutions per minute)
  • Logic: 4 channels *

* Cable B-513 is required. Pulse or logic can be selected

4 channels for alarm / trigger

There are 4 channels available for alarms. This also requires cable B-513.

Large, easy-to-read display

The HV GL2000 has a large 7-inch colour display (800 x 480). Measurement data can be displayed in a waveform display or as digital values. Parameter settings can be checked on the screen.

Long-term recording of 4 million measurements per channel

Measurement value acquisition in the device's internal RAM and 4 GB flash memory, continuous measurement value acquisition up to a file size of 4 GB.

  • Large internal RAM (4 million measurements per channel)
  • External data recording on USB memory and SD memory card

Measurement duration

  • Internal RAM (4 million measurements per channel) 4 seconds @ 1 µs interval; 46 days @ 1s interval
  • Integrated flash memory (3.9 GB) 3.5 days @ 1 ms; more than 1 year @ 1s
  • External memory (SD memory card / USB stick) 4 days @ 1ms; more than 1 year @ 1s

Standard software GL 980_2000-APS

  • Automatic search for connected devices
  • different display formats: YT curve, XY curve and digital values
  • Support real-time data transmission up to a sampling interval of 1 ms (also from internal RAM).
  • Acquired data stored in binary format can be converted to CSV format.

Operation and configuration

The buttons are ergonomically arranged for easy access and operation with gloves. Measurement signals are connected via the integrated M3 screw terminals. Data recording can be started and stopped manually on the device, via an external trigger or time-controlled. The individually adjustable alarm output can be used to monitor the individual measuring channels and offers in addition to min or max. Configuration and data recording are also possible directly on the PC via a USB interface.

Input terminal block

channels 4 analogue input channels
Voltage ranges ± 20, ± 50, ± 100, ± 200, ± 500 mV; ± 1, ± 2, ± 5, ± 10, ± 20, ± 50, ± 100, ± 200, ± 500 V, ± 1000 V
Voltage ranges DC-RMS 10, 25, 50, 100, 250, 500 mV rms, 1, 2.5, 5, 10, 25, 50, 100, 250, 500, 1000 V rms Final value range
Maximum measuring voltage: 600 V rms
Thermocouples Type K, J, E, T, R, S, B, N, W
Filter (low-pass) Off, line (1.5 Hz), 5, 50, 500 Hz, 5, 50 kHz (at -3dB, -6dB / oct)

Main unit

4 pulse / logic channels max. 100,000 pulses per measurement interval, requires option B-513 alarm output cable
4 alarm outputs Open collector, can be activated from any channel, requires option B-513 alarm output cable
Getting things going for starting or stopping the measurement via date/time, measured value, status or counter input (LOW active)
Measurement intervals 1, 10, 100 µs, 1, 10 ms, 100, 200, 500 ms, 1, 2, 5, 10, 20, 30 s, 1 m
connections BNC for voltage inputs
, screw terminals for thermocouples
resolution 16 bit for internal acquisition
Storage 4 GB flash
storage on USB stick (maximum file size 4 GB)
Screen 5.7-inch (145 mm) colour TFT
couple Ethernet, USB
Power supply Power supply unit: 100 to 240 V, 50/60 Hz
DC input: 8.5 to 24 VDC
Battery B-569 (optional): Lithium-ion battery 7.2 V DC, 2900 mAh, 2 packs required
Dimensions Approx. 256 x 161 x 83 mm (with rubber protective cover)
Weight Approx. 1.3 kg (without AC adapter and battery)

Download datasheet

Download manual