Fluke 3000 FC series wireless multimeter

View. Save. Share.

All the facts, right on location. The Fluke 3000 FC True-RMS wireless multimeter with the Fluke Connect™ app and ShareLive™ video call function.

With its accuracy, reliability and ease of use, the Fluke 3000 FC wireless multimeter is the ideal solution for professional technicians. Independently tested for safe use in CAT IV 600 V/ CAT III 1000 V environments, the Fluke 3000 FC has all the features you need to investigate and troubleshoot many problems in electrical and electronic systems.

The Fluke 3000 FC offers True-RMS voltage and current measurement functions, 6000-count resolution and manual and automatic range setting, and it can perform frequency, capacitance and resistance measurements as well as dial-through and diode tests. In addition, the Fluke 3000 FC offers a higher base accuracy of 0.09%, a digital display showing up to three secondary readings from remote modules and a bright white backlight.

Fluke's 3000 FC series wireless multimeter with the Fluke Connect™ app has all the necessary functions and features for easy troubleshooting when testing and measuring.

  • AC and DC voltage measurements up to 1000 V
  • AC and DC current measurements with 0.01 mA resolution
  • Continuity test, resistance measurement, diode test, capacitance and frequency measurements
  • MIN/MAX registration
  • CAT III 1000 V, Cat IV 600 V; IP54

Plus, Fluke Connect wireless-compatible modules measure AC, DC and AC+DC voltage, AC and DC current and temperature, all of which are displayed on Fluke's 3000 FC series wireless multimeter. Choose a standard current clamp or a flexible current clamp to measure AC current. Mix and match modules to meet your unique measurement needs. Read the primary measurement value on the main display, and data from up to three modules at the same time. Modules are available individually, or as part of Fluke Connect kits.

 

 

 

Detailed specifications

AC voltage

Reach1

Resolution

Accuracy234

45 Hz to 500 Hz

500 Hz to 1 kHz

600.0 mV

0.1 mV

1,0% + 3

2,0% + 3

6,000 V

0,001 V

60,00 V

0,01 V

600,0 V

0,1 V

1000 V

1 V

1 All AC voltage ranges are specified from 1% of range to 100% of range.
2 Crest factor ≤ 3 at full scale up to 500 V, with linear decrease to crest factor < 1.5 at 1000 V.
3 For non-sinusoidal waveforms, add normal ± (2% of readout + 2% of full scale) for a crest factor of up to 3.
4 Make sure 107 V-Hz is not exceeded.

DC voltage, continuity, resistance, diode test and capacitance

Function

Reach

Resolution

Accuracy

mV

600.0 mV

0.1 mV

0,09% + 2

V

6,000 V

0,001 V

0,09% + 2

60,00 V

0,01 V

600,0 V

0,1 V

1000 V

1 V

0,15% + 2

Ω

600 Ω

1 Ω

Meter beeps at < 25 Ω, beeper recognises interruptions or short circuits of 250 μs or longer.

Ω

600,0 Ω

0,1 Ω

0,5% + 2

6,000 kΩ

0.001 kΩ

0,5% + 1

60.00 kΩ

0.01 kΩ

60.00 kΩ

0.1 kΩ

600.0 kΩ

0.001 MΩ

50.00 MΩ

0.01 MΩ

1,5% + 3

Diode test

2,000 V

0,001 V

1% + 2

µF

1000 nF

1 nF

1,2% + 2

10.00 μF

0.01 μF

100.0 μF

0.1 μF

9999 μF1

1 μF

Normal 10%

1 In the range of 9999 μF for measurements up to 1000 μF, the measurement accuracy is 1.2% + 2.

AC and DC current

Function

Reach1

Resolution

Accuracy

mA AC
(45 Hz to 1 kHz)

60.00 mA

0.01 mA

1,5% + 3

400.0 mA3

0.1 mA

mA DC2

60.00 mA

0.01 mA

0,5% + 3

400.0 mA3

0.1 mA

1 All AC ranges are specified from 5% of range to 100% of range.
2 Load voltage inputs (normal): 400mA input 2 mV/mA.
3 400.0 mA accuracy specified up to 600 mA overload.

Frequency

Reach

Resolution

Accuracy1

 

99.99 Hz

0.01 Hz

0,1% + 1

 

999.9 Hz

0.1 Hz

 

9.999 kHz

0.001 kHz

 

99.99 kHz

0.01 kHz

 

1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.

 

Input characteristics

Function

Overload
security

Input impedance
(nominal)

Common-mode suppression ratio (1 kΩ asymmetric)

Normal-mode suppression

http://www.fluke.com/NR/rdonlyres/02E19193-32CF-4FCC-9BE2-B33A7240CAF5/0/fucntion_1_05.gif” height=”22″ width=”27″>

1100 V RMS

> 10 MΩ < 100 pF

> 120 dB at DC, 50 Hz or 60 Hz

> 60 dB at 50 Hz or 60 Hz

http://www.fluke.com/NR/rdonlyres/307AF02A-6AC2-469C-B147-F81A8F33822D/0/fucntion_2_05.gif” height=”20″ width=”27″>

1100 V RMS

> 10 MΩ < 100 pF

> 60 dB, DC to 60 Hz

 

http://www.fluke.com/NR/rdonlyres/43437E60-728F-4AE1-8739-FBED4BE855C0/0/fucntion_3_05.gif” height=”29″ width=”24″>

1100 V RMS

> 10 MΩ < 100 pF

> 120 dB at DC, 50 Hz or 60 Hz

> 60 dB at 50 Hz or 60 Hz

No-load test voltage

Tension full scale

Normal short-circuit current

Up to 6 MΩ

50 MΩ

http://www.fluke.com/NR/rdonlyres/00BBE998-BBC5-40FC-8DF5-EF48FDCEF500/0/fucntion_4_05.gif” height=”17″ width=”38″>

1100 V RMS

< 2.7 V DC

< 0.7 V DC

< 0.9 V DC

< 350 mA

http://www.fluke.com/NR/rdonlyres/B30DDB4A-47CD-476E-9CED-F16984A8A49D/0/fucntion_5_05.gif” height=”18″ width=”37″>

1100 V RMS

< 2.7 V DC

2,000 V DC

< 1.1 mA

mA function

Surge protector

Fuse, 44/100 A, 1000 V FAST

Overload

600 mA overload for maximum 2 minutes, minimum 10 minutes rest

MIN/MAX registration accuracy

DC functions

The specified accuracy of the measurement function ± 12 counts for changes lasting > 350 mS.

AC functions

The specified accuracy of the measurement function ± 40 counts for changes lasting > 900 mS.

General specifications

Maximum voltage between any connection and the safety earth

1000 V DC or AC RMS

Ω fuse of A inputs

0.44 A (44/100 A, 440 mA), 1000 V FAST fuse, specified Fluke part only

LCD display

Refresh rate: 4/sec
volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacity: 1000 counts

Battery type

Three AA alkaline batteries, NEDA 15A IEC LR6

Battery life

Minimum 250 hours

RF communication

2.4 GHz ISM band

RF communication range

Outside air, unobstructed: up to 20 m
Obstructed, plasterboard wall: up to 6.5 m
Blocked, concrete wall or steel electrical cabinet: up to 3.5 m

Temperature

Operation: -10 °C to 50 °C
Storage: -40 °C to 60 °C

Temperature coefficient

0.1 X (specified accuracy) /°C (28 °C)

Relative humidity

0% to 90% (0 °C to 35 °C)
0% to 75% (35 °C to 40 °C)
0% to 45% (40 °C to 50 °C)

Height

Company: 2000 m
Storage: 12,000 m

Electromagnetic compatibility
EMI, RFI, EMC, RF

EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC part 15 subpart C sections 15.207, 15.209, 15.249
FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE

Safety specifications

ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CAN/CSA-C22.2 no. 61010-1-12: 3rd edition
UL 61010-1: 3rd edition
IEC/EN 61010-1:2010

Certifications

CSA, FCC, CE

Protection class (IP)

IP54

Pollution degree

2

Dimensions (H x W x D)

4.75 cm x 9.3 cm x 20.7 cm
(1.87 inches x 3.68 inches x 8.14 inches)

Weight

340 g

Note: not suitable for Fluke CNX measuring instruments

 

Download datasheet

Need advice?

Contact our product specialist Thiara for help in choosing the right instrument.
Contact Thiara

Select at least 2 products