Fluke's 3000 FC series wireless multimeter with the Fluke Connect™ app has all the necessary functions and features for easy troubleshooting when testing and measuring.
- AC and DC voltage measurements up to 1000 V
- AC and DC current measurements with 0.01 mA resolution
- Continuity test, resistance measurement, diode test, capacitance and frequency measurements
- MIN/MAX registration
- CAT III 1000 V, Cat IV 600 V; IP54
Plus, Fluke Connect wireless-compatible modules measure AC, DC and AC+DC voltage, AC and DC current and temperature, all of which are displayed on Fluke's 3000 FC series wireless multimeter. Choose a standard current clamp or a flexible current clamp to measure AC current. Mix and match modules to meet your unique measurement needs. Read the primary measurement value on the main display, and data from up to three modules at the same time. Modules are available individually, or as part of Fluke Connect kits.
|
Detailed specifications
|
|
AC voltage
|
|
Reach1
|
Resolution
|
Accuracy234
|
|
45 Hz to 500 Hz
|
500 Hz to 1 kHz
|
|
600.0 mV
|
0.1 mV
|
1,0% + 3
|
2,0% + 3
|
|
6,000 V
|
0,001 V
|
|
60,00 V
|
0,01 V
|
|
600,0 V
|
0,1 V
|
|
1000 V
|
1 V
|
|
1 All AC voltage ranges are specified from 1% of range to 100% of range. 2 Crest factor ≤ 3 at full scale up to 500 V, with linear decrease to crest factor < 1.5 at 1000 V. 3 For non-sinusoidal waveforms, add normal ± (2% of readout + 2% of full scale) for a crest factor of up to 3. 4 Make sure 107 V-Hz is not exceeded.
|
|
DC voltage, continuity, resistance, diode test and capacitance
|
|
Function
|
Reach
|
Resolution
|
Accuracy
|
|
mV
|
600.0 mV
|
0.1 mV
|
0,09% + 2
|
|
V
|
6,000 V
|
0,001 V
|
0,09% + 2
|
|
60,00 V
|
0,01 V
|
|
600,0 V
|
0,1 V
|
|
1000 V
|
1 V
|
0,15% + 2
|
|
Ω
|
600 Ω
|
1 Ω
|
Meter beeps at < 25 Ω, beeper recognises interruptions or short circuits of 250 μs or longer.
|
|
Ω
|
600,0 Ω
|
0,1 Ω
|
0,5% + 2
|
|
6,000 kΩ
|
0.001 kΩ
|
0,5% + 1
|
|
60.00 kΩ
|
0.01 kΩ
|
|
60.00 kΩ
|
0.1 kΩ
|
|
600.0 kΩ
|
0.001 MΩ
|
|
50.00 MΩ
|
0.01 MΩ
|
1,5% + 3
|
|
Diode test
|
2,000 V
|
0,001 V
|
1% + 2
|
|
µF
|
1000 nF
|
1 nF
|
1,2% + 2
|
|
10.00 μF
|
0.01 μF
|
|
100.0 μF
|
0.1 μF
|
|
9999 μF1
|
1 μF
|
Normal 10%
|
|
1 In the range of 9999 μF for measurements up to 1000 μF, the measurement accuracy is 1.2% + 2.
|
|
AC and DC current
|
|
Function
|
Reach1
|
Resolution
|
Accuracy
|
|
mA AC (45 Hz to 1 kHz)
|
60.00 mA
|
0.01 mA
|
1,5% + 3
|
|
400.0 mA3
|
0.1 mA
|
|
mA DC2
|
60.00 mA
|
0.01 mA
|
0,5% + 3
|
|
400.0 mA3
|
0.1 mA
|
|
1 All AC ranges are specified from 5% of range to 100% of range. 2 Load voltage inputs (normal): 400mA input 2 mV/mA. 3 400.0 mA accuracy specified up to 600 mA overload.
|
|
Frequency
|
|
Reach
|
Resolution
|
Accuracy1
|
|
|
99.99 Hz
|
0.01 Hz
|
0,1% + 1
|
|
|
999.9 Hz
|
0.1 Hz
|
|
|
9.999 kHz
|
0.001 kHz
|
|
|
99.99 kHz
|
0.01 kHz
|
|
|
1 Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
|
|
|
Input characteristics
|
|
Function
|
Overload security
|
Input impedance (nominal)
|
Common-mode suppression ratio (1 kΩ asymmetric)
|
Normal-mode suppression
|
|
http://www.fluke.com/NR/rdonlyres/02E19193-32CF-4FCC-9BE2-B33A7240CAF5/0/fucntion_1_05.gif” height=”22″ width=”27″>
|
1100 V RMS
|
> 10 MΩ < 100 pF
|
> 120 dB at DC, 50 Hz or 60 Hz
|
> 60 dB at 50 Hz or 60 Hz
|
|
http://www.fluke.com/NR/rdonlyres/307AF02A-6AC2-469C-B147-F81A8F33822D/0/fucntion_2_05.gif” height=”20″ width=”27″>
|
1100 V RMS
|
> 10 MΩ < 100 pF
|
> 60 dB, DC to 60 Hz
|
|
|
http://www.fluke.com/NR/rdonlyres/43437E60-728F-4AE1-8739-FBED4BE855C0/0/fucntion_3_05.gif” height=”29″ width=”24″>
|
1100 V RMS
|
> 10 MΩ < 100 pF
|
> 120 dB at DC, 50 Hz or 60 Hz
|
> 60 dB at 50 Hz or 60 Hz
|
|
No-load test voltage
|
Tension full scale
|
Normal short-circuit current
|
|
Up to 6 MΩ
|
50 MΩ
|
|
http://www.fluke.com/NR/rdonlyres/00BBE998-BBC5-40FC-8DF5-EF48FDCEF500/0/fucntion_4_05.gif” height=”17″ width=”38″>
|
1100 V RMS
|
< 2.7 V DC
|
< 0.7 V DC
|
< 0.9 V DC
|
< 350 mA
|
|
http://www.fluke.com/NR/rdonlyres/B30DDB4A-47CD-476E-9CED-F16984A8A49D/0/fucntion_5_05.gif” height=”18″ width=”37″>
|
1100 V RMS
|
< 2.7 V DC
|
2,000 V DC
|
< 1.1 mA
|
|
mA function
|
|
Surge protector
|
Fuse, 44/100 A, 1000 V FAST
|
|
Overload
|
600 mA overload for maximum 2 minutes, minimum 10 minutes rest
|
|
MIN/MAX registration accuracy
|
|
DC functions
|
The specified accuracy of the measurement function ± 12 counts for changes lasting > 350 mS.
|
|
AC functions
|
The specified accuracy of the measurement function ± 40 counts for changes lasting > 900 mS.
|
|
General specifications
|
|
Maximum voltage between any connection and the safety earth
|
1000 V DC or AC RMS
|
|
Ω fuse of A inputs
|
0.44 A (44/100 A, 440 mA), 1000 V FAST fuse, specified Fluke part only
|
|
LCD display
|
Refresh rate: 4/sec volts, amps, ohms: 6000 counts Frequency: 10,000 counts Capacity: 1000 counts
|
|
Battery type
|
Three AA alkaline batteries, NEDA 15A IEC LR6
|
|
Battery life
|
Minimum 250 hours
|
|
RF communication
|
2.4 GHz ISM band
|
|
RF communication range
|
Outside air, unobstructed: up to 20 m Obstructed, plasterboard wall: up to 6.5 m Blocked, concrete wall or steel electrical cabinet: up to 3.5 m
|
|
Temperature
|
Operation: -10 °C to 50 °C Storage: -40 °C to 60 °C
|
|
Temperature coefficient
|
0.1 X (specified accuracy) /°C (28 °C)
|
|
Relative humidity
|
0% to 90% (0 °C to 35 °C) 0% to 75% (35 °C to 40 °C) 0% to 45% (40 °C to 50 °C)
|
|
Height
|
Company: 2000 m Storage: 12,000 m
|
|
Electromagnetic compatibility EMI, RFI, EMC, RF
|
EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC part 15 subpart C sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE
|
|
Safety specifications
|
ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 no. 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010
|
|
Certifications
|
CSA, FCC, CE
|
|
Protection class (IP)
|
IP54
|
|
Pollution degree
|
2
|
|
Dimensions (H x W x D)
|
4.75 cm x 9.3 cm x 20.7 cm (1.87 inches x 3.68 inches x 8.14 inches)
|
|
Weight
|
340 g
|
Note: not suitable for Fluke CNX measuring instruments