| Electric |
| AC current: Bek |
| Reach |
999,9 A |
| Resolution |
0,1 A |
| Accuracy |
2% ± 5 digits (10 Hz to 100 Hz)
2.5% ± 5 digits (100 Hz to 500 Hz) |
| Crest factor (50/60 Hz) |
3 at 500 A
2.5 at 600 A
1.42 at 1000 A
Add 2% for C.F. > 2 |
| AC current: flexible current probe |
| Reach |
2500 A |
| Resolution |
1 A (≤ 2500 A), 0.1 A (≤ 999.9 A) |
| Accuracy |
3 % ±5 digits (5 Hz to 500 Hz) |
| Crest factor (50/60 Hz) |
3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Plus 2% for CF > 2 |
| Position sensitivity |
 |
Distance from optimum |
i2500-10 Flex |
i2500-18 Flex |
Error |
| A |
0.5 in (12.7 mm) |
1.4 in (35.6 mm) |
± 0.5 % |
| B |
0.8 in (20.3 mm) |
2.0 in (50.8 mm) |
± 1.0 % |
| C |
1.4 in (35.6 mm) |
2.5 in (63.5 mm) |
± 2.0 % |
| Measurement uncertainty, assuming the primary conductor is in an optimal position, no external electric or magnetic field is present and the operating temperature range is not exceeded. |
| DC current |
| Reach |
999,9 A |
| Resolution |
0,1 A |
| Accuracy |
2% ±5 digits1 |
| [1]When using the ZERO function to compensate for zero deviations. |
| AC voltage: FieldSense |
| Reach |
1000 V |
| Resolution |
1 V (≤1000V) |
| Accuracy |
≤ 4/0 AWG |
3 % ±5 digits (45 Hz to 66 Hz) |
| ≥ 4/0 AWG |
5 % ±5 digits (45 Hz to 66 Hz) |
Place the wire as close as possible to the jaw opening (see illustration).  |
| AC voltage: Measurement leads |
| Reach |
600.0 V 1000 V |
| Resolution |
0.1 V (≤600.0 V)
1 V (≤1000 V) |
| Accuracy |
1 % ±5 digits (20 Hz to 500 Hz) |
| DC voltage |
| Reach |
600,0 V
1000 V |
| Resolution |
0.1 V (≤600.0 V)
1 V (≤1000 V) |
| Accuracy |
1 % ± 5 digits |
| mV DC |
| Reach |
500.0 mV |
| Resolution |
0.1 mV |
| Accuracy |
1 % ± 5 digits |
| Amp frequency: Bek |
| Reach |
5.0 Hz to 500.0 Hz |
| Resolution |
0.1 Hz |
| Accuracy |
0.5 % ±5 digits |
| Trigger level |
5 Hz to 10 Hz, ≥ 10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A |
| Amp frequency: Flexible current probe |
| Reach |
5.0 Hz to 500.0 Hz |
| Resolution |
0.1 Hz |
| Accuracy |
0.5 % ±5 digits |
| Trigger level |
5 Hz to 20 Hz, ≥ 25 A
20 Hz to 100 Hz, ≥ 20 A
100 Hz to 500 Hz, ≥ 25 A |
| Resistance |
| Reach |
60.00 kΩ
6000 Ω
600,0 Ω |
| Resolution |
0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60.00 kΩ) |
| Accuracy |
1 % ± 5 digits |
| Capacity |
| Reach |
1000 μF |
| Resolution |
0.1 μF (≤100.0 μF)
1 μF (≤1000 μF) |
| Accuracy |
1 % ±4 digits |
| Mechanical |
| Dimensions (L x W x H) |
274 mm x 86 mm x 47 mm |
| Weight (with batteries) |
463 g |
| Jaw-opening |
34 mm |
| Diameter flexible current clamp |
7.5 mm |
| Cable length flexible current clamp (from head to electronic connector) |
1,8 m |
| Rogowski coil length |
450 mm |
| Environmental conditions |
| Operating temperature |
-10 °C to 50 °C |
| Storage temperature |
-40 °C to 60 °C |
| Operating humidity (without condensation) |
Non-condensing (< 10 °C)
≤ 90% RH (10 °C to 30 °C)
≤ 75% RH (30 °C to 40 °C)
≤ 45% RH (40 °C to 50 °C) |
| Temperature coefficient |
Plus 0.1 x the specified accuracy for each degree C > 28 °C or < 18 °C |
| Protection class |
IEC 60529: IP30 (jaws closed) |
| Operating height |
2000 m |
| Height when stored |
12.000 m |
| Electromagnetic compatibility (EMC) |
| International |
IEC 61326-1: Electromagnetic environment, portable equipment
IEC 61326-2-2, CISPR 11: Group 1, Class B |
| Group 1: The equipment has deliberately generated and/or uses conductively coupled high-frequency energy required for the internal functioning of the equipment itself. |
Class B: Equipment is suitable for use in homes and buildings directly connected to a low-voltage power supply network for residential buildings.
If the equipment is connected to an object under test, emissions greater than the levels defined by CISPR 11 may occur. |
| South Korea (KCC) |
Class A equipment (industrial transmission and communication equipment) |
| Class A: The equipment meets the requirements for industrial (Class A) electromagnetic radiation equipment, and the seller and user should take this into account. This equipment is intended for use in business environments and is not intended for home use. |
| US (FCC) |
47 CFR 15 subpart B. This product is considered an exempt device under clause 15.103. |
| Safety |
| General |
IEC 61010-1: Pollution degree 2 |
| Measurement |
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V |
| Current clamp for leakage current measurement |
IEC 61557-13: Class 2, ≤30 A/m |
| Wireless radio |
| Radio frequency certification |
FCC-ID: T68-FBLE IC:6627A-FBLE |
| Frequency range |
2405 MHz to 2480 MHz |
| Output power |
<100 mW |
| Radio frequency data |
Radio Frequency Data For Class A Devices
SIMPLIFIED EU DECLARATION OF CONFORMITY
Fluke hereby declares that the radio equipment in this Product complies with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf. |