FLUKE 729 Automatic pressure calibrator

  • Automatic pressure build-up and control up to 300 psi
  • Easy process documentation with built-in test templates
  • Automatic internal pressure fine-tuning
  • Measuring, generating and simulating signals from 4 to 20 mA
  • 24V loop power supply for powering transmitters for tests
  • Bright two/three-channel colour graphic display
  • HART communication for testing smart HART transmitters
  • Built-in leak test for checking test fixtures for leaks
  • Robust portable design with 3-year warranty as standard
  • Compatibility with the Fluke Connect® app
  • Temperature measurements with optional 720RTD thermocouple
  • Measuring V DC for testing transmitters with an output of 1 V DC to 5 V DC
  • Compatible with 700-series and 750-series printing modules
  • Uploading documented test results to the DPCTrack2â„¢ calibration management software
  • Innovative semi-rigid carrying case specially designed for on-site work

Automatic pressure generation and control up to 300 psi (20 bar, 2MPa) Enter a pressure and the 729 will automatically pump until the desired pressure is reached. Enter a test template and the 729 will automatically pump and document a multi-point pressure calibration test.

Easy documentation of calibration using defined templates for transmitters and switches. Type in the starting and ending pressures and the number of measurement points. The 729 does the rest by documenting the applied pressure, measured mA values and % error for each measuring point. The bright colour graphic display warns in red of test results that are out of tolerance.

Automatic internal pressure fine-tuning helps compensate for small leaks in hoses and test set-ups. There is then no need to turn a fine adjuster to compensate for leaks, eliminating manual pumping and manual fine adjustment of test set-ups.

HART communication enables adjustment of the mA output signal, applied values and pressure zero of HART pressure transmitters. You can perform light configuration tasks such as changing a transmitter tag, measurement units and range setting. Other supported HART tasks include setting fixed mA output signals for troubleshooting, reading equipment configuration and variables, and reading equipment diagnostic data.

Measure mA signals on transmitter outputs, generate and simulate mA signals for testing I/Ps and other mA loop devices. andIncludes a 24V loop power supply for testing and powering transmitters during individual tests while the transmitters are disconnected from the control system.

The robust portable design
Thoroughly tested and guaranteed to withstand a 1-metre drop, the 729 is suitable for on-site instrument calibration. With a choice of three ranges, namely 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), the Fluke 729 automatic pressure calibrators are designed to perform when and where you need them. Temperature measurements with optional 720RTD probe for performing transfer calibrations. A standard, semi-rigid carrying case specifically designed for on-site work, to store test hoses, fittings, test leads and small hand tools making it easy to carry everything needed for on-site pressure calibrations.

Fluke Connect® compatibility lets a user perform remote monitoring tasks using the Fluke Connect mobile app, as well as manage and store pressure measurements and log events. Share measurements using ShareLive™ video calls and emails.

Temperature measurements with optional 720RTD thermocouple for performing transfer calibrations.

Pressure measurements with pressure modules of the old 700-series and the new 750-series when different pressure measurement ranges or resolutions are desired.

Support in several languages:: select a language in the instrument configuration programme. HART communication commands are limited to English, according to the descriptors and protocol of HART devices.

Semi-rigid carrying case is specially designed for on-site work, to store test hoses, fittings, test leads and small hand tools for on-site pressure calibrations.

Portable automatic pressure calibrator simplifies pressure calibration

The Fluke 729 automatic pressure calibrator was designed specifically with process engineers in mind. This pressure calibrator simplifies the pressure calibration process and provides faster, more accurate test results. Technicians know that calibrating pressure can be a time-consuming task, but the 729 makes it easier than ever: with an electric pump that automatically builds and regulates pressure in one easy-to-use, rugged, portable package.

The 729 is the ideal portable pressure calibrator, on which you simply type in a desired pressure value after which the calibrator automatically pumps until the desired set point is reached. Then the internal fine adjustment automatically stabilises the pressure to the requested value.

The Fluke 729 can also automatically test multiple pressure measurement points and automatically document the results. Calibration is as simple as typing in the initial and final pressure, number of measurement points and tolerance level. The 729 does the rest.

Built-in HART communication capabilities allow adjustment of mA settings of HART transmitters, light HART configurations, and tuning to applied 0% and 100% values.

Upload and manage documented calibration results with DPCTrack2â„¢ calibration management software, making it easy to manage your instruments, create scheduled checks and reports, and manage calibration data.

With a choice of three ranges, namely 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), the Fluke 729 automatic pressure calibrators are designed to perform when and where you need them.

Printing specification*
Annual specification 0.02% of full scale
Operation specification minimum 0.005% of full scale
*See manual for detailed specifications
Model
729 30G
Psi range, resolution -12,0000 to 30,0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment No wireless communication
729 150G
Psi range, resolution -12,000 to 150,000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment No wireless communication
729 300G
Psi range, resolution -12,000 to 300,000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment No wireless communication
729 30G FC
Psi range, resolution -12,0000 to 30,0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment Wireless communication for Fluke Connect
729 150G FC
Psi range, resolution -12,000 to 150,000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment Wireless communication for Fluke Connect
729 300G FC
Psi range, resolution -12,000 to 300,000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment Wireless communication for Fluke Connect
729CN 200K
Psi range, resolution -12,0000 to 30,0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment For China, no wireless communication
729CN 1M
Psi range, resolution -12,000 to 150,000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment For China, no wireless communication
729CN 2M
Psi range, resolution -12,000 to 300,000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment For China, no wireless communication
729CN 200K FC
Psi range, resolution -12,0000 to 30,0000 psi
Bar range, resolution -0.82737 to 2.06842 bar
kPa range, resolution -82.737 to 206.843 kPa
Comment For China, wireless communication for Fluke Connect
729CN 1M FC
Psi range, resolution -12,000 to 150,000 psi
Bar range, resolution -0.8273 to 10.3421 bar
kPa range, resolution -82.73 to 1034.21 kPa
Comment For China, wireless communication for Fluke Connect
729CN 2M FC
Psi range, resolution -12,000 to 300,000 psi
Bar range, resolution -0.8273 to 20.6843 bar
kPa range, resolution -82.73 to 2068.43 kPa
Comment For China, wireless communication for Fluke Connect
729JP 200K
kPa range, resolution -82.737 to 206.843 kPa
Comment For Japan, no wireless communication
729JP 1M
kPa range, resolution -82.73 to 1034.21 kPa
Comment For Japan, range 1 MPa, no wireless communication
729JP 2M
kPa range, resolution -82.73 to 2068.43 kPa
Comment For Japan, range 2 MPa, no wireless communication
729JP 200K FC
kPa range, resolution -82.737 to 206.843 kPa
Comment For Japan, wireless communication for Fluke Connect
729JP 1M FC
kPa range, resolution -82.73 to 1034.21 kPa
Comment For Japan, wireless communication for Fluke Connect
729JP 2M FC
kPa range, resolution -82.73 to 2068.43 kPa
Comment For Japan, wireless communication for Fluke Connect
Electrical specification
All specifications apply up to 110% of range, except for 24 mA generation and simulation, which apply up to 100% of range.
Reach
Measure, generate and simulate mA 0 mA to 24 mA
Measuring DC voltage 0 V DC to 30 V DC
Resolution
Generate, simulate and measure mA DC 1 μA
DC voltage measurement 1 mV
Accuracy 0.01% ± 2 digits in all ranges (at 23 °C ± 5 °C)
Stability 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C
External voltage required for mA simulation 12 V DC to 30 V DC
Applied loop voltage 24 V DC at 20 mA
External voltage required for mA simulation 12 V DC to 30 V DC
Temperature measurement only/100 Ω Pt(385) RTD -50 °C to 150 °C (-58 °F to 302 °F)
Temperature resolution 0,01 °C (0,01 °F)
Temperature accuracy ± 0.1 °C (0.2 °F) ± 0.25 °C (± 0.45 °F) combined accuracy when using the 720 RTD thermocouple (optional accessory)
Permissible load resistance 1200 Ω without HART resistor, 950 Ω with internal HART resistor
Mechanical specification
Dimensions (h x w x l) 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
Weight 2.95 kg
Protection class IP54
Environment specification
Operating temperature -10 °C to 50 °C for metering, 0 °C to 50 °C for pressure control
Operating temperature with battery -10 °C to 40 °C
Battery can only be charged up to 40 °C
Storage temperature -40 °C to 60 °C
Operating height 3000 m
Height when stored 13000 m
Wireless (729 FC only)
Radio frequency certification FCC ID: T68-FBLE IC:6627A-FBLE
RF range for wireless communication 2412 MHz to 2462 MHz

Download datasheet

Need advice?

Contact our product specialist Thiara for help in choosing the right instrument.
Contact Thiara

Select at least 2 products