Fluke 377 FC True-RMS-AC/DC current clamp with iFlex®

Producer: Fluke
  • Measure voltage and current with your current clamp
  • Faster and safer testing, all without touching a live wire, with FieldSense™ technology.
  • Full 3-phase voltage and current testing in fewer steps
  • Voltage and current measurements with FieldSense™ technology

    The Fluke 377 FC True-RMS current clamp offers faster and safer testing, all without touching a live wire, with FieldSense™ technology. You get accurate voltage and current measurements through the pliers' jaws. Simply clamp the black test wire to an electrical earth wire, place the jaws of the pliers around the wire and see reliable, accurate voltage and current readings on the screen.

    Measure extremely high currents with the iFlex® sensor

    Use the included iFlex flexible current probe to measure AC current up to 2500 A AC. The iFlex flexible current clamps provide access to thick conductors in tight spaces.

    Fast, simple, full 3-phase measurements

    • Complete 3-phase voltage and current testing in three easy steps
    • Full set calculating phase-to-ground and phase-to-phase values
    • Displayed on your smartphone and stored in the cloud via Fluke Connect software
    • Phase rotation calculated and displayed on Fluke Connect software
    • No more handwritten notes or complicated arithmetic.

    Easy to read, easy to use with tools included

    Your job gets easier when you use the 377 FC current clamp. The display turns green when a stable FieldSense reading is detected. Visual transit also provides a bright green display for easy detection of transit in noisy areas.

    Record, analyse and share results with Fluke Connect® software

    Fluke Connect software lets you remotely capture, track and monitor measurements to find alternate problems. With Fluke Connect, you can also collect data as a basis for a preventive maintenance programme.

General specifications
General maximum voltage between each connection and earthing 1000 V
Battery Type 2 AA IEC LR6 alkaline
Lifetime 200 hours
Display Dual readout
Automatic switch-off 20 minutes
Electric
AC current: Bek
Reach 999,9 A
Resolution 0,1 A
Accuracy 2% ± 5 digits (10 Hz to 100 Hz)
2.5% ± 5 digits (100 Hz to 500 Hz)
Crest factor (50/60 Hz) 3 at 500 A
2.5 at 600 A
1.42 at 1000 A
Add 2% for C.F. > 2
AC current: flexible current probe
Reach 2500 A
Resolution 1 A (≤ 2500 A), 0.1 A (≤ 999.9 A)
Accuracy 3 % ±5 digits (5 Hz to 500 Hz)
Crest factor (50/60 Hz) 3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Plus 2% for CF > 2
Position sensitivity
Flexible current clamp Distance from optimum i2500-10 Flex i2500-18 Flex Error
A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 %
B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 %
C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 %
Measurement uncertainty, assuming the primary conductor is in an optimal position, no external electric or magnetic field is present and the operating temperature range is not exceeded.
DC current
Reach 999,9 A
Resolution 0,1 A
Accuracy 2% ±5 digits1
[1]When using the ZERO function to compensate for zero deviations.
AC voltage: FieldSense
Reach 1000 V
Resolution 1 V (≤1000V)
Accuracy ≤ 4/0 AWG 3 % ±5 digits (45 Hz to 66 Hz)
≥ 4/0 AWG 5 % ±5 digits (45 Hz to 66 Hz)
Place the wire as close as possible to the jaw opening (see illustration).
AC voltage: Measurement leads
Reach 600.0 V 1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1 % ±5 digits (20 Hz to 500 Hz)
DC voltage
Reach 600,0 V
1000 V
Resolution 0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy 1 % ± 5 digits
mV DC
Reach 500.0 mV
Resolution 0.1 mV
Accuracy 1 % ± 5 digits
Amp frequency: Bek
Reach 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % ±5 digits
Trigger level 5 Hz to 10 Hz, ≥ 10 A
10 Hz to 100 Hz, ≥ 5 A
100 Hz to 500 Hz, ≥ 10 A
Amp frequency: Flexible current probe
Reach 5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5 % ±5 digits
Trigger level 5 Hz to 20 Hz, ≥ 25 A
20 Hz to 100 Hz, ≥ 20 A
100 Hz to 500 Hz, ≥ 25 A
Resistance
Reach 60.00 kΩ
6000 Ω
600,0 Ω
Resolution 0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
10 Ω (≤60.00 kΩ)
Accuracy 1 % ± 5 digits
Capacity
Reach 1000 μF
Resolution 0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy 1 % ±4 digits
Mechanical
Dimensions (L x W x H) 274 mm x 86 mm x 47 mm
Weight (with batteries) 463 g
Jaw-opening 34 mm
Diameter flexible current clamp 7.5 mm
Cable length flexible current clamp (from head to electronic connector) 1,8 m
Rogowski coil length 450 mm
Environmental conditions
Operating temperature -10 °C to 50 °C
Storage temperature -40 °C to 60 °C
Operating humidity (without condensation) Non-condensing (< 10 °C)
≤ 90% RH (10 °C to 30 °C)
≤ 75% RH (30 °C to 40 °C)
≤ 45% RH (40 °C to 50 °C)
Temperature coefficient Plus 0.1 x the specified accuracy for each degree C > 28 °C or < 18 °C
Protection class IEC 60529: IP30 (jaws closed)
Operating height 2000 m
Height when stored 12.000 m
Electromagnetic compatibility (EMC)
International IEC 61326-1: Electromagnetic environment, portable equipment
IEC 61326-2-2, CISPR 11: Group 1, Class B
Group 1: The equipment has deliberately generated and/or uses conductively coupled high-frequency energy required for the internal functioning of the equipment itself.
Class B: Equipment is suitable for use in homes and buildings directly connected to a low-voltage power supply network for residential buildings.
If the equipment is connected to an object under test, emissions greater than the levels defined by CISPR 11 may occur.
South Korea (KCC) Class A equipment (industrial transmission and communication equipment)
Class A: The equipment meets the requirements for industrial (Class A) electromagnetic radiation equipment, and the seller and user should take this into account. This equipment is intended for use in business environments and is not intended for home use.
US (FCC) 47 CFR 15 subpart B. This product is considered an exempt device under clause 15.103.
Safety
General IEC 61010-1: Pollution degree 2
Measurement IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
Current clamp for leakage current measurement IEC 61557-13: Class 2, ≤30 A/m
Wireless radio
Radio frequency certification FCC-ID: T68-FBLE IC:6627A-FBLE
Frequency range 2405 MHz to 2480 MHz
Output power <100 mW
Radio frequency data Radio Frequency Data For Class A Devices
SIMPLIFIED EU DECLARATION OF CONFORMITY
Fluke hereby declares that the radio equipment in this Product complies with Directive 2014/53/EU. The full text of the EU declaration is available at the following internet address: https://dam-assets.fluke.com/s3fs-public/FLK_RED_1aeng0900.pdf.

Need advice?

Contact our product specialist Thiara for help in choosing the right instrument.
Contact Thiara

Select at least 2 products
to compare