Additel 780 Automatic pressure controller

Features

  • Pressure ranges from vacuum to 200 bar
  • Pressure ranges from vacuum to 3,000 psi (200 bar)
  • Accuracy of models up to 0.01% of reading
  • Standard model accuracy of 0.02% of full scale
  • HART communication and Profibus PA (not included with ADT780S)
  • Control stability of 0.003%FS
  • User-friendly icon-based interface
  • ISO 17025-accredited calibration with/data included

For years, we have supplied the most durable, accurate quality pressure calibration products for field applications. The Additel The 780 automatic pressure controller contains the same durability, accuracy and quality in a new desktop controller packed with features and functionality that is remarkably easy to use.

The Additel 780 automatic pressure controller offers two basic ranges: up to 1,000 psi (70 bar) and up to 3,000 psi (200 bar). The basic range defines the maximum control range of the controller. Each configuration includes a control sensor that allows you to pre-select the sensor range best suited for your application. External and internal sensors can be used, allowing for future expansion of range and accuracy.

Modular design
Each unit comes with one Intelligent Pressure Module configured for the many available ranges. The Standard Accuracy sensors (ADT160A-CPXXX) are silicon pressure sensors with a 1-year accuracy of 0.02% FS. The quartz-based Precision sensors improve the 1-year accuracy specification to 0.005% of reading + 0.005% FS. Each sensor is specially aged, tested and screened for assembly. After assembly, each sensor is temperature compensated over a range of -10°C to 50°C. The Additel 780 is capable of one internal pressure sensor and one external pressure sensor. The modular design of this unit allows both the internal and external sensors to be interchangeable with other Intelligent Pressure Modules. In addition to the Intelligent Pressure Modules, the Additel 780 has a built-in barometric sensor. This allows for switching from gauge pressure to absolute pressure.

Standalone solution
Typical pressure calibrators require a nitrogen cylinder for gas supply, making it difficult to move the calibrator without having to connect or move another cylinder. The Additel 780 is unique as with the optional electric pump you can generate pressures up to 1,000 psi (70 bar) without the need for a gas cylinder.

Process functionality
The 780 pressure controller is suitable for a wide range of applications that typically require a pressure calibrator. Its built-in capabilities include current and voltage measurements, 24-volt loop power, HART® and Profibus PA communication, switch measurement capabilities, selectable analogue output, and much more.

Specification ADT780-1K ADT780-3K
Pressure range:  -0.95 to 70 bar and -0.95 to 200 bar[1].
Control stability:  0.003% FS (stability based on % FS of control sensor range)
Precision (includes 1 year stability):  See pressure range table
1 Year stability:  0.01% FS standard accuracy sensors
0.005% FS precision accuracy sensors
Media:  Clean gas
Over-range indication:  103% to 120% (based on sensor)
Resolution: 4, 5, 6, or 7 digits (user selectable)[2].
Pressure type:  Gauge, Absolute
Warm up time:  15 minutes
Typical pressure settling time(within 0.003%FS):  20 seconds (10%FS pressure change assuming 50 mL test volume)
Measurement units: Pa, hPa, kPa, MPa, bar, mbar, psi, mmHg@0°C,cmHg@0°C, mHg@0°C, inHg@0°C, inH2O@4°C, mmH2O@4°C, cmH2O@4°C, mH2O@4°C, mmH2O@20°C, cmH2O@20°C, mH2O@20°C, kg/m2, kg/cm2, mtorr, torr, atm, lb/ft2, tsi, user selectable
Minimum control pressure[3]: 0.0001 psi 0.001 psi
[1] Gas booster or HP gas supply required to reach 3,000 psi (200 bar). Booster ordered separately.
[2] 7 digit resolution for precision model only.
[3] Dependent on pressure module.
[4] Barometer sensor: (0~120)kPa, 0.05%FS (0.01%FS is optional)

Precision Quartz Sensors

P/N Pressure Range Media Accuracy Suggested controller Internal/ External
AP45Q 0 to 2.0 bar G 0.005% rdg + 0.005% FS ADT780-1K only Both
AP100Q 0 to 7.0 bar G 0.005% rdg + 0.005% FS ADT780-1K only Both
AP400Q 0 to 28 bar G 0.005% rdg + 0.005% FS Both Both
AP500Q 0 to 35 bar G 0.005% rdg + 0.005% FS Both Both
AP1KQ 0 to 70 bar G 0.005% rdg + 0.005% FS Both Both
AP2KQ 0 to 140 bar G 0.005% rdg + 0.005% FS ADT780-3K only Both
AP3KQ 0 to 200 bar G 0.005% rdg + 0.005% FS ADT780-3K only Both

 

Standard Pressure Sensors

P/N Pressure Range Media Accuracy Suggested controller Internal/ External
CP10 ±10 ±0.7 G 0.02% FS ADT780-1K only Both
CP15 ±15 ±1.0 G 0.02% FS ADT780-1K only Both
CP30 -1 to 2.0 bar G 0.02% FS ADT780-1K only Both
CP50 -1 to 3.5 bar G 0.02% FS ADT780-1K only Both
CP100 -1 to 7.0 bar G 0.02% FS ADT780-1K only Both
CP300 -1 to 20 bar G 0.02% FS Both Both
CP500 -1 to 35 bar G 0.02% FS Both Both
CP600 -1 to 40 bar G 0.02% FS Both Both
CP1K -1 to 70 bar G 0.02% FS Both Both
CP2K -1 to 140 bar G 0.02% FS ADT780-3K only Both
CP3K -1 to 200 bar G 0.02% FS ADT780-3K only Both
CP5K -1 to 350 bar G 0.02% FS N/A External
CP10K -1 to 700 bar G 0.02% FS N/A External
Download Datasheet Download Additel pump and booster

Need advice?

Contact our product specialist Thiara for help in choosing the right instrument.
Contact Thiara

Select at least 2 products