{"id":9693,"date":"2024-10-04T10:35:32","date_gmt":"2024-10-04T10:35:32","guid":{"rendered":"https:\/\/lhm-instrumentation.eu\/?post_type=product&#038;p=9693"},"modified":"2024-10-04T10:35:32","modified_gmt":"2024-10-04T10:35:32","slug":"imageur-acoustique-fluke-ii915","status":"publish","type":"product","link":"https:\/\/lhm-instrumentation.eu\/fr\/product\/fluke-ii915-acoustic-imager\/","title":{"rendered":"Imagerie acoustique Fluke ii915"},"content":{"rendered":"<p><span style=\"font-size: large;\"><strong>Fluke ii915 Acoustic Imager : d\u00e9tecter, localiser et \u00e9valuer les anomalies<\/strong><\/span><\/p>\n<p>L'imageur acoustique Fluke ii915 est un outil puissant con\u00e7u pour identifier et \u00e9valuer les probl\u00e8mes dans divers syst\u00e8mes. Avec trois modes diff\u00e9rents - LeakQ\u2122, PDQ\u2122 et MecQ\u2122 - cet appareil innovant permet aux professionnels de la maintenance de prendre des mesures proactives et d'\u00e9viter des probl\u00e8mes co\u00fbteux. Jetons un coup d'\u0153il aux caract\u00e9ristiques :<\/p>\n<p><span style=\"font-size: large;\"><strong>D\u00e9tection des fuites avec une plus grande sensibilit\u00e9<\/strong><\/span><br \/>\n<strong>Mode LeakQ\u2122 : d\u00e9tection des co\u00fbts cach\u00e9s<\/strong><\/p>\n<p>Les fuites dans les syst\u00e8mes d'air comprim\u00e9, de gaz, de vapeur et de vide peuvent entra\u00eener des pertes financi\u00e8res importantes. Le Fluke ii915 simplifie la d\u00e9tection des fuites en permettant aux techniciens de visualiser le son. Pendant qu'ils scrutent les tuyaux, les raccords et les connexions, le r\u00e9seau acoustique int\u00e9gr\u00e9 enregistre les niveaux de d\u00e9cibels par fr\u00e9quence. L'application SoundMap\u2122 qui en r\u00e9sulte est superpos\u00e9e \u00e0 une image visuelle, ce qui facilite la localisation des fuites, m\u00eame pendant les heures de pointe. Dites adieu aux inspections fastidieuses et r\u00e9pondez \u00e0 une d\u00e9tection efficace des fuites. Le Fluke ii915 dispose d'une gamme de fr\u00e9quences \u00e9lev\u00e9es et de la meilleure sensibilit\u00e9 pour effectuer une d\u00e9tection acoustique des fuites plus efficace.<\/p>\n<p><span style=\"font-size: large;\"><strong>Identification pr\u00e9coce des probl\u00e8mes m\u00e9caniques<\/strong><\/span><br \/>\n<strong>Mode MecQ\u2122 : inspection efficace des syst\u00e8mes de convoyage<\/strong><\/p>\n<p>Les syst\u00e8mes de bandes transporteuses sont connus pour leur complexit\u00e9 et le risque d'interruption de la production. La cam\u00e9ra acoustique Fluke ii915 r\u00e9volutionne les inspections en permettant le balayage sans contact de grandes zones. Le filtrage avanc\u00e9 du bruit garantit des images claires, m\u00eame dans les environnements tr\u00e8s bruyants. La d\u00e9tection pr\u00e9coce des probl\u00e8mes m\u00e9caniques potentiels permet une maintenance cibl\u00e9e, \u00e9vitant ainsi les temps d'arr\u00eat impr\u00e9vus. Pour un fonctionnement sans faille et une maintenance proactive des grands syst\u00e8mes de convoyage, l'imageur acoustique Fluke ii915 avec MecQ\u2122 est le choix ultime.<\/p>\n<p><span style=\"font-size: large;\"><strong>Visualiser la menace invisible<\/strong><\/span><br \/>\n<strong>Mode PDQ\u2122 : localisation des d\u00e9charges partielles<\/strong><\/p>\n<p>Les d\u00e9charges partielles pr\u00e9sentent des risques s\u00e9rieux, de l'arc \u00e9lectrique \u00e0 la panne de courant. Le Fluke ii915 traduit les sons des d\u00e9charges partielles en images visuelles, indiquant avec pr\u00e9cision l'emplacement. Avec une plage de fr\u00e9quences \u00e9tendue de 2 \u00e0 100 kHz, cet instrument peut d\u00e9tecter les d\u00e9charges partielles encore plus t\u00f4t et contribuer \u00e0 la planification de la maintenance afin d'\u00e9viter les \u00e9v\u00e9nements catastrophiques. Les \u00e9lectriciens haute tension, les ing\u00e9nieurs \u00e9lectriciens et les \u00e9quipes de maintenance du r\u00e9seau peuvent d\u00e9sormais voir ce qui \u00e9tait auparavant invisible.<\/p>","protected":false},"excerpt":{"rendered":"<h2 class=\"features-title\">Caract\u00e9ristiques principales<\/h2>\n<div id=\"keyfeature_content\" data-readmore=\"\" aria-expanded=\"true\">\n<ul>\n<li><strong>Am\u00e9lioration des performances :<\/strong>\u00a0Am\u00e9lioration des performances de d\u00e9tection des fuites de gaz, des d\u00e9charges \u00e9lectriques et des probl\u00e8mes m\u00e9caniques.<\/li>\n<li><strong>Mode LeakQ\u2122 :<\/strong>\u00a0Estimation de la taille de la fuite et estimation du co\u00fbt.<\/li>\n<li><strong>Mode PDQ\u2122 :<\/strong>\u00a0\u00c9value la gravit\u00e9 de la d\u00e9charge.<\/li>\n<li><strong>Mode MecQ\u2122 :<\/strong>\u00a0 Traiter de mani\u00e8re proactive les probl\u00e8mes potentiels des composants m\u00e9caniques rotatifs.<\/li>\n<li><strong>Fonctions de rapport :<\/strong>\u00a0Fonctionnalit\u00e9 int\u00e9gr\u00e9e de marquage et d'annotation visuelle et textuelle pour des rapports rationalis\u00e9s.<\/li>\n<li><strong>T\u00e9l\u00e9chargement sans fil :<\/strong>\u00a0Transfert facile des donn\u00e9es vers Fluke Connect.<\/li>\n<\/ul>\n<\/div>","protected":false},"featured_media":9694,"template":"","meta":[],"product_brand":[],"product_cat":[267,182],"product_tag":[],"class_list":["post-9693","product","type-product","status-publish","has-post-thumbnail","product_cat-lekdetectie","product_cat-ultrasoon","first","instock","shipping-taxable","product-type-simple"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fluke ii915 Acoustic Imager - LHM Instrumentation<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lhm-instrumentation.eu\/fr\/produit\/imageur-acoustique-fluke-ii915\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fluke ii915 Acoustic Imager - LHM Instrumentation\" \/>\n<meta property=\"og:description\" content=\"Belangrijkste kenmerken    Verbeterde prestaties:\u00a0Verbeterde detectieprestaties voor gaslekken, elektrische ontladingen en mechanische problemen.  LeakQ\u2122-modus:\u00a0Geschatte lekgrootte en kostenschatting.  PDQ\u2122-modus:\u00a0Beoordeelt de ernst van de ontlading.  MecQ\u2122-modus:\u00a0 Potenti\u00eble problemen in roterende mechanische componenten proactief aanpakken.  Rapportfuncties:\u00a0Ge\u00efntegreerde functionaliteit voor visuele en tekstuele tagging en aantekeningen voor gestroomlijnde rapportage.  Draadloos uploaden:\u00a0Eenvoudige overdracht van gegevens naar Fluke Connect.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lhm-instrumentation.eu\/fr\/produit\/imageur-acoustique-fluke-ii915\/\" \/>\n<meta property=\"og:site_name\" content=\"LHM Instrumentation\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lhm-instrumentation.eu\/wp-content\/uploads\/2024\/10\/F-ii915-01a.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture est.\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/\",\"url\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/\",\"name\":\"Fluke ii915 Acoustic Imager - LHM Instrumentation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/F-ii915-01a.webp\",\"datePublished\":\"2024-10-04T10:35:32+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/#breadcrumb\"},\"inLanguage\":\"fr-BE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-BE\",\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/#primaryimage\",\"url\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/F-ii915-01a.webp\",\"contentUrl\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/wp-content\\\/uploads\\\/2024\\\/10\\\/F-ii915-01a.webp\",\"width\":1500,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/product\\\/fluke-ii915-acoustic-imager\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Producten\",\"item\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Fluke ii915 Acoustic Imager\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/#website\",\"url\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/\",\"name\":\"LHM Instrumentation\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lhm-instrumentation.eu\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-BE\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Imagerie acoustique Fluke ii915 - LHM Instrumentation","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lhm-instrumentation.eu\/fr\/produit\/imageur-acoustique-fluke-ii915\/","og_locale":"fr_FR","og_type":"article","og_title":"Fluke ii915 Acoustic Imager - LHM Instrumentation","og_description":"Belangrijkste kenmerken    Verbeterde prestaties:\u00a0Verbeterde detectieprestaties voor gaslekken, elektrische ontladingen en mechanische problemen.  LeakQ\u2122-modus:\u00a0Geschatte lekgrootte en kostenschatting.  PDQ\u2122-modus:\u00a0Beoordeelt de ernst van de ontlading.  MecQ\u2122-modus:\u00a0 Potenti\u00eble problemen in roterende mechanische componenten proactief aanpakken.  Rapportfuncties:\u00a0Ge\u00efntegreerde functionaliteit voor visuele en tekstuele tagging en aantekeningen voor gestroomlijnde rapportage.  Draadloos uploaden:\u00a0Eenvoudige overdracht van gegevens naar Fluke Connect.","og_url":"https:\/\/lhm-instrumentation.eu\/fr\/produit\/imageur-acoustique-fluke-ii915\/","og_site_name":"LHM Instrumentation","og_image":[{"width":1500,"height":1000,"url":"https:\/\/lhm-instrumentation.eu\/wp-content\/uploads\/2024\/10\/F-ii915-01a.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture est.":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/","url":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/","name":"Imagerie acoustique Fluke ii915 - LHM Instrumentation","isPartOf":{"@id":"https:\/\/lhm-instrumentation.eu\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/#primaryimage"},"image":{"@id":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/#primaryimage"},"thumbnailUrl":"https:\/\/lhm-instrumentation.eu\/wp-content\/uploads\/2024\/10\/F-ii915-01a.webp","datePublished":"2024-10-04T10:35:32+00:00","breadcrumb":{"@id":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/#breadcrumb"},"inLanguage":"fr-BE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/"]}]},{"@type":"ImageObject","inLanguage":"fr-BE","@id":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/#primaryimage","url":"https:\/\/lhm-instrumentation.eu\/wp-content\/uploads\/2024\/10\/F-ii915-01a.webp","contentUrl":"https:\/\/lhm-instrumentation.eu\/wp-content\/uploads\/2024\/10\/F-ii915-01a.webp","width":1500,"height":1000},{"@type":"BreadcrumbList","@id":"https:\/\/lhm-instrumentation.eu\/product\/fluke-ii915-acoustic-imager\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lhm-instrumentation.eu\/"},{"@type":"ListItem","position":2,"name":"Producten","item":"https:\/\/lhm-instrumentation.eu\/shop\/"},{"@type":"ListItem","position":3,"name":"Fluke ii915 Acoustic Imager"}]},{"@type":"WebSite","@id":"https:\/\/lhm-instrumentation.eu\/#website","url":"https:\/\/lhm-instrumentation.eu\/","name":"LHM Instrumentation","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lhm-instrumentation.eu\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-BE"}]}},"_links":{"self":[{"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/product\/9693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/media\/9694"}],"wp:attachment":[{"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/media?parent=9693"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/product_brand?post=9693"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/product_cat?post=9693"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/lhm-instrumentation.eu\/fr\/wp-json\/wp\/v2\/product_tag?post=9693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}